Product Description
TT-01-406081A-00500 Sailor 6081 Power Supply, Charger, Wall Mount Tray
It also charges automatically a connected battery.
If the AC power fails the power supply delivers DC power from the connected battery.
You can access control and monitoring data via the Ethernet interface.
There are relay outputs for AC outage and battery voltage alarm.
The power supply provides up to 1480 W in total.
The following configurations are available:
SAILOR 6081: Max. 370 W
SAILOR 6081 with 1 additional SAILOR 6080: Max. 740 W
SAILOR 6081 with 2 additional SAILOR 6080: Max. 1110 W
SAILOR 6081 with 3 additional SAILOR 6080: Max. 1480 W
Depending on the output power needed, the Power Supply Unit and Charger includes up to four SAILOR 6080 units and one connector panel.
The SAILOR 6081 can be upgraded on site to more output power by adding up to three SAILOR 6080 units.
The connectors for DC power are placed at the same end of the unit for easy mounting and installation.
The connection between the Power Supply unit(s) and the connector panel are protected against water ingress by a protection cover.
A cable relief bracket to secure heavy cables is integrated in the wall-mount tray.
Overview
TT-01-406081A-00500
The Power Supply Unit and Charger has the following features:
Output voltage according to battery requirements (range: 24 — 31.2 V)
15 V DC output for SAILOR 3027 Terminal
DC connectors, 2 x 10 A, 2 x 20 A and 1 x 50 A
Up to 1480 W peak output power
AC input (100-240 VAC operating) with fuse (6.3 A) with Power Factor Correction
Automatic detection of input voltage range
AC alarm and battery voltage alarm
Ethernet connector for monitoring and control information
Battery charging function
Short circuit protection
Over-temperature protection (shutdown with automatic restart)
Switch over to battery power in case of AC supply failure
No forced cooling required
Link to control up to 8 Power Supply Unit and Charger units connected to the same battery
Upgrade on site by service personnel
IP 32 for internal high voltage areas (>42 V), IP 22 in other areas when vertically mounted (wall) and connector panel is facing down1
Approval and certification: IEC 60945 Maritime approval, Wheelmark
Tech Specs
TT-01-406081A-00500
DC output (nominal): 28 V or according to battery requirements.
Alarm: In case of AC power failure or if battery power is outside allowed range
IP rating in high voltage (>42 V): IP 32 (mounted vertically on wall)
IP rating in other areas: IP 22 (mounted vertically on wall)
The following table shows the electrical and environmental specifications of
the Power Supply Unit and Charger.
OUTPUT POWER:
100 — 240 VAC continuous peak (2 min.)
SAILOR 6081: 300W, 370W
SAILOR 6081 1 SAILOR 6080: 600W, 740W
SAILOR 6081 2 SAILOR 6080: 900W, 1110W
SAILOR 6081 3 SAILOR 6080: 1200W, 1480W
90 — 100 VAC continuous peak (2 min.)
SAILOR 6081: 270W, 333W
SAILOR 6081 1 SAILOR 6080: 500W, 616W
SAILOR 6081 2 SAILOR 6080: 730W, 899W
SAILOR 6081 3 SAILOR 6080: 960W, 1182W
ENVIRONMENTAL
Operating temperature -15° to 55° C
Storage temperature -40° to 80° C
Cooling No forced cooling required.
Survival temperature (power on) -40° to 80° C
MECHANICAL
Dimensions and Weights
SAILOR 6081: H: 66 mm, L: 590 mm, W: 355 mm, Wt: 6.2kg
SAILOR 6081 1 SAILOR 6080: H: 112 mm, L: 590 mm, W: 355 mm, Wt: 10.1kg
SAILOR 6081 2 SAILOR 6080: H: 158 mm, L: 590 mm, W: 355 mm, Wt: 14.0kg
SAILOR 6081 3 SAILOR 6080: H: 204 mm, L: 590 mm, W: 355 mm, Wt: 17.9kg
6080 POWER SUPPLY – NOT INCLUDED
The following tables show the electrical and environmental specifications of the AC/DC Power Supply.
Specifications Value
Output power at 100 VAC – 240 VAC 300 W continuous, 370 W peak (2 min.)
Output power at 90 VAC – 100 VAC 270 W continuous, 333 W peak (2 min.)
DC output (nominal) 31.2 VDC at 0 A, 29.3 VDC at 10 A, 28.7 VDC at 13 A
AC input voltage 115-230 VAC nominal, 100-240 VAC operating
Alarm: In case of AC power failure
IP rating in high voltage (>42 V) IP 3X
IP rating in other areas IP 2X
IP rating when mounted vertically on a wall IP X2
Operating temperature -25° to 55° C
Storage temperature -40° to 80° C
Cooling: No forced cooling required.
Survival temperature (power on) -40° to 80° C
Dimensions: H: 46.5 mm, L: 354 mm, W: 265 mm
Weight Approx. 3.7 kg
6081 POWER LOAD
In case of AC power failure or overload a battery connected to the SAILOR 6081 Power Supply Unit and Charger delivers the required power seamlessly.
Note that output power has a higher priority than the charging current.
To load deeply discharged batteries (battery voltage lower than 23 V) the Power Supply Unit and Charger has a pre-charge mode. Regular charging starts as soon as the battery voltage is above 23 V.
The maximum charging current and the nominal battery voltage can be adjusted.
For further details see Customizing battery settings on page 33 of the user manual
6080 POWER SUPPLY INFO
The 6080 AC/DC Power Supply can deliver 300 W output power on average with a peak of 370 W for a minimum of 2 minutes.
The AC/DC Power Supply has an on/off switch, It is lit when the power is turned on.
All connectors are placed at the same end of the power supply to simplify mounting and installation, the connector panel is protected by a transparent lid.
To secure an installation with heavy cables an optional Wall Tray / cable relief bracket can be installed(order part# TT-01-406080A-001)
Included Wall Mounting Tray / Cable Relief Bracket
When mounted vertically the AC/DC Power Supply fulfills IP32 in areas with more than 42 V and IP22 in other areas. This means that the unit is protected against the intrusion of solid objects (including body parts like fingers), dust, water etc.
Use this tray To secure an installation with heavy cables.
When mounted vertically the AC/DC Power Supply fulfills IP32 in areas with more than 42 V and IP22 in other areas.
This means that the unit is protected against the intrusion of solid objects (including body parts like fingers), dust, water etc.
When more power is needed than one power supply can give, i.e. 300 W, you can stack up to three power supplies on top of each other and connect them.
When stacking 2 or 3 units the load on each of the units is automatically balanced among the units.
Stacking multiple units
You can mount up to three AC/DC Power Supply units in a vertical (recommended to use the Wall Mounting Tray and cable-relief bracket, heavy duty, order number: Part# 406080A-001) or horizontal position.
When mounted in a vertical position, with the connector panel pointing downwards, the unit fulfills IP32 in areas with more than 42 V and IP22 in other areas.
The mounting holes in the AC/DC Power Supply are designed in such a way that units fit nicely on top of each other when being stacked.
IMPORTANT NOTES
To ensure adequate cooling of the AC/DC Power Supplies an unobstructed space of minimum 5 cm must be maintained around all sides of the group of units (except between the units and the bottom side).
Output power capability depend on the mounting position (horizontal or vertical), input voltage, ambient temperature and ventilation at the place of installation.
Compass safe distance 30 cm